with UG11
Spectrum 65: ????BE13 Edit
DeleteMeasurement
Brand |
Exo Terra Rolf C. Hagen Inc. http://www.hagen.com/ |
---|---|
Lamp Product |
Solar Glo 160W |
Lamp ID |
????BE13 (11/2007) |
Spectrometer | USB 2000 |
Ballast | - no ballast or default/unknown ballast - |
Reflector | |
Distance | 30 cm |
Age | 105 hours |
Originator (measurement) | Frances Baines |
Colorimetry
Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.
WARNING: The measurement range (350 - 800 nm) is not sufficient for this evaluation! Data is only available in the range 270.05 - 750.92 nm. Results are shown anyway but should be ignored by anyone except experts.
Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (id 1).
From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338 – 451, 511 – 513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.
Human (CIE) | 3 cone reptile | 4 cone reptile | |
---|---|---|---|
Cone Excitation | |||
Colour Coordinate | ( 0.33 ; 0.39 ) | ( 0.13 ; 0.36 ) | ( 0.27 ; 0.092 ; 0.26 ) |
CCT | 5500 Kelvin | 0 Kelvin | 8100 Kelvin |
distance | 0 | 0.17 | |
colour space | 3-D-graph not implemented yet |
Vitamin D3 Analysis
Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.
This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.
The ratio of the two solarmeters 6.2 (UVB) and 6.5 (UV index) readings has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.
Effective Irradiances
Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.
The calculation method is a numerical implementation (Simpson's rule) of the formula
To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).
The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists
- range: UVB (US) = 13.8 µW/cm²
- radiometer: Solarmeter 6.2 = 19.6 µW/cm²
total ( 0 nm - 0 nm) 3900 µW/cm² = 39 W/m² UVC ( 0 nm - 280 nm) -2.99 µW/cm² = -0.0299 W/m² non-terrestrial ( 0 nm - 290 nm) -4.59 µW/cm² = -0.0459 W/m² total2 ( 250 nm - 880 nm) 3900 µW/cm² = 39 W/m² UVB (EU) ( 280 nm - 315 nm) 62.3 µW/cm² = 0.623 W/m² UVB (US) ( 280 nm - 320 nm) 67 µW/cm² = 0.67 W/m² UVA+B ( 280 nm - 380 nm) 1030 µW/cm² = 10.3 W/m² Solar UVB ( 290 nm - 315 nm) 63.8 µW/cm² = 0.638 W/m² UVA D3 regulating ( 315 nm - 335 nm) 52.7 µW/cm² = 0.527 W/m² UVA (EU) ( 315 nm - 380 nm) 965 µW/cm² = 9.65 W/m² UVA2 (medical definition) ( 320 nm - 340 nm) 59.9 µW/cm² = 0.599 W/m² UVA (US) ( 320 nm - 380 nm) 960 µW/cm² = 9.6 W/m² UVA1 (variant) ( 335 nm - 380 nm) 912 µW/cm² = 9.12 W/m² UVA1 (medical) ( 340 nm - 400 nm) 927 µW/cm² = 9.27 W/m² vis. UVA ( 350 nm - 380 nm) 883 µW/cm² = 8.83 W/m² VIS Rep3 ( 350 nm - 600 nm) 3390 µW/cm² = 33.9 W/m² VIS Rep4 ( 350 nm - 700 nm) 3620 µW/cm² = 36.2 W/m² purple ( 380 nm - 420 nm) 327 µW/cm² = 3.27 W/m² VIS ( 380 nm - 780 nm) 2880 µW/cm² = 28.8 W/m² VIS2 ( 400 nm - 680 nm) 2650 µW/cm² = 26.5 W/m² PAR ( 400 nm - 700 nm) 2710 µW/cm² = 27.1 W/m² tmp ( 400 nm - 1100 nm) 2850 µW/cm² = 28.5 W/m² blue ( 420 nm - 490 nm) 626 µW/cm² = 6.26 W/m² green ( 490 nm - 575 nm) 794 µW/cm² = 7.94 W/m² yellow ( 575 nm - 585 nm) 727 µW/cm² = 7.27 W/m² orange ( 585 nm - 650 nm) 129 µW/cm² = 1.29 W/m² red ( 650 nm - 780 nm) 275 µW/cm² = 2.75 W/m² IRA ( 700 nm - 1400 nm) 144 µW/cm² = 1.44 W/m² IR2 ( 720 nm - 1100 nm) 87.4 µW/cm² = 0.874 W/m² IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
Erythema 0.309 UV-Index Pyrimidine dimerization of DNA 24.6 µW/cm² Photoceratitis 2.02 µW/cm² Photoconjunctivitis -2.25 µW/cm² DNA Damage -3.05 Vitamin D3 8.13 µW/cm² Photosynthesis 1710 µW/cm² Luminosity 10300 lx Human L-Cone 1530 µW/cm² Human M-Cone 1320 µW/cm² Human S-Cone 604 µW/cm² CIE X 1270 µW/cm² CIE Y 1470 µW/cm² CIE Z 1060 µW/cm² PAR 13800000 mol photons Extinction preD3 36.9 e-3*m²/mol Extinction Tachysterol 134 e-3*m²/mol Exctincition PreD3 2110 m²/mol Extinction Lumisterol -27.9 m²/mol Exctincition Tachysterol 196000 m²/mol Extinction 7DHC -39.9 m²/mol L-Cone 1300 µW/cm² M-Cone 443 µW/cm² S-Cone 1260 µW/cm² U-Cone 1810 µW/cm² UVR - ICNIRP 2004 -2.69 Rel Biol Eff Melatonin Supression 688 µW/cm² Blue Light Hazard 703 µW/cm² (68.1 µW/cm² per 1000 lx) CIE 174:2006 PreVit D3 8.57 µW/cm² Lumen Reptil 10200 "pseudo-lx" Vitamin D3 Degradation 8.79 µW/cm² Actinic UV -2.72 µW/cm² (-2.63 mW/klm) Exctincition Lumisterol -28200 m²/mol Exctincition 7DHC -41500 m²/mol Exctincition Toxisterols 1890 m²/mol
Solarmeter 6.2 (UVB, pre 2010) 66.3 µW/cm² Solarmeter 6.5 (UV-Index, pre 2010) 1.32 Leybold UVB 58 µW/cm² Leybold UVA 683 µW/cm² Leybold UVC -1.14 µW/cm² DeltaOhm UVB 95.3 µW/cm² DeltaOhm UVC 9.49 µW/cm² Vernier UVB 19 µW/cm² Vernier UVA 274 µW/cm² Gröbel UVA 839 µW/cm² Gröbel UVB 28.1 µW/cm² Gröbel UVC -1.8 µW/cm² Luxmeter 11200 lx Solarmeter 6.4 (D3) 4.12 IU/min UVX-31 133 µW/cm² IL UVB 0.0282 µW/cm² IL UVA 896 µW/cm² Solarmeter 6.5 (UVI, post 2010) 1.81 UV-Index Solarmeter 6.2 (UVB, post 2010) 39.5 µW/cm² (Solarmeter Ratio = 21.8) Solarmeter AlGaN 6.5 UVI sensor 41.1 UV Index GenUV 7.1 UV-Index 2.15 UV-Index Solarmeter 10.0 (Global Power) (manuf.) 33.8 W/m² Solarmeter 4.0 (UVA) 11.8 mW/cm² LS122 (manuf.) 0 W/m² ISM400 (first guess) 20.5 W/m² LS122 (assumption) 1.05 W/m² ISM400_new 16.2 W/m² Solarmeter 10.0 (Global Power) (assumption) 30.3 W/m²