Reptile Lamp Database

Spectrum 500: TRX-R1 Edit
Delete

Full Spectrum

Reserve Lamp - 100h use

Measurement

Brand Trixie
Trixie Reptiland www.trixie.de Germany
Lamp Product Reptiland Desert Pro UV-B 10.0
Research project c/o Oonincx et al 2012
Lamp ID TRX-R1 (04/2014)
Reserve Lamp
Spectrometer USB2000+ (2)
Ballast - no ballast or default/unknown ballast -
Reflector
Distance 10 cm
Age 100 hours
Originator (measurement) Frances Baines
Database entry created: Frances Baines 29/Apr/2014 ; updated: Frances Baines 29/Apr/2014

Colorimetry

Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.

Spectrum in the visible wavelength range

Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (id 1).

From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338451, 511513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.

Human (CIE) 3 cone reptile 4 cone reptile
Cone Excitation
Colour Coordinate ( 0.29 ; 0.28 ) ( 0.23 ; 0.5 ) ( 0.21 ; 0.18 ; 0.39 )
CCT 9700 Kelvin 10000 Kelvin 8700 Kelvin
distance 0.17 0.13
colour space 3-D-graph not implemented yet

Vitamin D3 Analysis

Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.

This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.

Spectrum in the vitamin D3 active wavelength range

The ratio of the two solarmeters 6.2 (UVB) and 6.5 (UV index) readings has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.

Effective Irradiances

Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.

The calculation method is a numerical implementation (Simpson's rule) of the formula

To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).

The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists

  • range: UVB (US) = 13.8 µW/cm²
  • radiometer: Solarmeter 6.2 = 19.6 µW/cm²
then any Solarmeter 6.2 reading multiplied with 0.7 (0.7=13.8/19.6) is an estimate of UVB irradiance for this specific lamp. If you do so, always make sure, that the calculated (effective) irradiance is valid. The calculated value is not valid, if the lamp's spectrum is not measured in the relevant range.

Ranges
total ( 0 nm - 0 nm) 1360 µW/cm² = 13.6 W/m²
UVC ( 0 nm - 280 nm) 0 µW/cm² = 0 W/m²
non-terrestrial ( 0 nm - 290 nm) 0 µW/cm² = 0 W/m²
total2 ( 250 nm - 880 nm) 1360 µW/cm² = 13.6 W/m²
UVB (EU) ( 280 nm - 315 nm) 60.7 µW/cm² = 0.607 W/m²
UVB (US) ( 280 nm - 320 nm) 102 µW/cm² = 1.02 W/m²
UVA+B ( 280 nm - 380 nm) 528 µW/cm² = 5.28 W/m²
Solar UVB ( 290 nm - 315 nm) 60.7 µW/cm² = 0.607 W/m²
UVA D3 regulating ( 315 nm - 335 nm) 195 µW/cm² = 1.95 W/m²
UVA (EU) ( 315 nm - 380 nm) 468 µW/cm² = 4.68 W/m²
UVA2 (medical definition) ( 320 nm - 340 nm) 213 µW/cm² = 2.13 W/m²
UVA (US) ( 320 nm - 380 nm) 426 µW/cm² = 4.26 W/m²
UVA1 (variant) ( 335 nm - 380 nm) 273 µW/cm² = 2.73 W/m²
UVA1 (medical) ( 340 nm - 400 nm) 226 µW/cm² = 2.26 W/m²
vis. UVA ( 350 nm - 380 nm) 113 µW/cm² = 1.13 W/m²
VIS Rep3 ( 350 nm - 600 nm) 744 µW/cm² = 7.44 W/m²
VIS Rep4 ( 350 nm - 700 nm) 916 µW/cm² = 9.16 W/m²
purple ( 380 nm - 420 nm) 105 µW/cm² = 1.05 W/m²
VIS ( 380 nm - 780 nm) 827 µW/cm² = 8.27 W/m²
VIS2 ( 400 nm - 680 nm) 771 µW/cm² = 7.71 W/m²
PAR ( 400 nm - 700 nm) 789 µW/cm² = 7.89 W/m²
tmp ( 400 nm - 1100 nm) 814 µW/cm² = 8.14 W/m²
blue ( 420 nm - 490 nm) 258 µW/cm² = 2.58 W/m²
green ( 490 nm - 575 nm) 202 µW/cm² = 2.02 W/m²
yellow ( 575 nm - 585 nm) 43.3 µW/cm² = 0.433 W/m²
orange ( 585 nm - 650 nm) 115 µW/cm² = 1.15 W/m²
red ( 650 nm - 780 nm) 105 µW/cm² = 1.05 W/m²
IRA ( 700 nm - 1400 nm) 25.2 µW/cm² = 0.252 W/m²
IR2 ( 720 nm - 1100 nm) 13.9 µW/cm² = 0.139 W/m²
IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
Actionspectra
Erythema 2.76 UV-Index
Pyrimidine dimerization of DNA 36.9 µW/cm²
Photoceratitis 4.46 µW/cm²
Photoconjunctivitis 0.0499 µW/cm²
DNA Damage 0.163
Vitamin D3 12.7 µW/cm²
Photosynthesis 568 µW/cm²
Luminosity 1930 lx
Human L-Cone 285 µW/cm²
Human M-Cone 246 µW/cm²
Human S-Cone 232 µW/cm²
CIE X 277 µW/cm²
CIE Y 267 µW/cm²
CIE Z 417 µW/cm²
PAR 3980000 mol photons
Extinction preD3 103 e-3*m²/mol
Extinction Tachysterol 369 e-3*m²/mol
Exctincition PreD3 49400 m²/mol
Extinction Lumisterol 8.42 m²/mol
Exctincition Tachysterol 554000 m²/mol
Extinction 7DHC 5.1 m²/mol
L-Cone 238 µW/cm²
M-Cone 207 µW/cm²
S-Cone 445 µW/cm²
U-Cone 244 µW/cm²
UVR - ICNIRP 2004 1.75 Rel Biol Eff
Melatonin Supression 288 µW/cm²
Blue Light Hazard 267 µW/cm² (139 µW/cm² per 1000 lx)
CIE 174:2006 PreVit D3 14 µW/cm²
Lumen Reptil 2440 "pseudo-lx"
Vitamin D3 Degradation 19.5 µW/cm²
Actinic UV 1.74 µW/cm² (9.05 mW/klm)
Exctincition Lumisterol 14700 m²/mol
Exctincition 7DHC 7550 m²/mol
Exctincition Toxisterols 9760 m²/mol
Broadbandmeters
Solarmeter 6.2 (UVB, pre 2010) 126 µW/cm²
Solarmeter 6.5 (UV-Index, pre 2010) 3.7
Leybold UVB 89.1 µW/cm²
Leybold UVA 309 µW/cm²
Leybold UVC 0.000891 µW/cm²
DeltaOhm UVB 240 µW/cm²
DeltaOhm UVC 27.1 µW/cm²
Vernier UVB 27.2 µW/cm²
Vernier UVA 344 µW/cm²
Gröbel UVA 396 µW/cm²
Gröbel UVB 41.7 µW/cm²
Gröbel UVC -0.0292 µW/cm²
Luxmeter 1990 lx
Solarmeter 6.4 (D3) 11.6 IU/min
UVX-31 262 µW/cm²
IL UVB 0.0539 µW/cm²
IL UVA 339 µW/cm²
Solarmeter 6.5 (UVI, post 2010) 3.25 UV-Index
Solarmeter 6.2 (UVB, post 2010) 88 µW/cm² (Solarmeter Ratio = 27)
Solarmeter AlGaN 6.5 UVI sensor 50.5 UV Index
GenUV 7.1 UV-Index 2.95 UV-Index
Solarmeter 10.0 (Global Power) (manuf.) 10.2 W/m²
Solarmeter 4.0 (UVA) 4.35 mW/cm²
LS122 (manuf.) 0 W/m²
ISM400 (first guess) 5.62 W/m²
LS122 (assumption) 0.26 W/m²
ISM400_new 4.47 W/m²
Solarmeter 10.0 (Global Power) (assumption) 8.49 W/m²