Spectrum #874 SW139 (Philips TL 8W/33-640) Edit
Delete(1) Raw Measurement
| Lampid | SW139 |
|---|---|
| Spectrometer | USB2000+ |
| Originator | Sarina Wunderlich |
| Ballast | - no ballast or default/unknown ballast - |
| Reflector | - no reflector - |
| Distance | 5 |
| Age | 1 |
CCT:1019 4086K
CRI DC:1017 6,44E-3
CRI R01:1002 57,6 (4086K)
CRI R02:1003 74,5 (4086K)
CRI R03:1004 89,4 (4086K)
CRI R04:1005 62,2 (4086K)
CRI R05:1006 59,1 (4086K)
CRI R06:1007 63,3 (4086K)
CRI R07:1008 72,6 (4086K)
CRI R08:1009 33,8 (4086K)
CRI R09:1010 -83,8 (4086K)
CRI R10:1011 41,2 (4086K)
CRI R11:1012 56,2 (4086K)
CRI R12:1013 45,8 (4086K)
CRI R13:1014 61,5 (4086K)
CRI R14:1015 94,2 (4086K)
CRI R15:1016 45,5 (4086K)
CRI Ra:1001 64,1 (4086K)
DC<5.4E-3:1018 false
X:1022 26,03
Y:1023 26,73
Z:1024 15,57
x:1026 0,3810
y:1027 0,3911
z:1028 0,2279
(2) Comparison of full spectrum to sunlight
(3) Colorimetry
Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.
Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (ASTM spectrum).
From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338 – 451, 511 – 513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.
| Human (CIE) | 3 cone reptile | 4 cone reptile | |
|---|---|---|---|
| Cone Excitation | |||
| Colour Coordinate | (0.38 ; 0.39) | (0.42 ; 0.45) | (0.43 ; 0.24 ; 0.26) |
| CCT | 4100 Kelvin | 4700 Kelvin | 3400 Kelvin |
| distance | 0.11 | 0.093 | |
| colour space | 3-D-graph not implemented yet |
(4) Vitamin D3 Analysis
Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.

This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.
The ratio of the readings of two solarmeters 6.2 (UVB) and 6.5 (UV index) has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.
(5) Effective Irradiances
Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.
The calculation method is a numerical implementation (Simpson's rule) of the formula
To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).
The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists
- range: UVB (US) = 13.8 µW/cm²
- radiometer: Solarmeter 6.2 = 19.6 µW/cm²
total ( 0 nm - 0 nm) 5620 µW/cm² = 56.2 W/m² UVC ( 0 nm - 280 nm) 5.01 µW/cm² = 0.0501 W/m² non-terrestrial ( 0 nm - 290 nm) 6.81 µW/cm² = 0.0681 W/m² total2 ( 250 nm - 880 nm) 5620 µW/cm² = 56.2 W/m² UVB (EU) ( 280 nm - 315 nm) 18.5 µW/cm² = 0.185 W/m² UVB (US) ( 280 nm - 320 nm) 19.7 µW/cm² = 0.197 W/m² UVA+B ( 280 nm - 380 nm) 100 µW/cm² = 1 W/m² Solar UVB ( 290 nm - 315 nm) 16.7 µW/cm² = 0.167 W/m² UVA D3 regulating ( 315 nm - 335 nm) 4.93 µW/cm² = 0.0493 W/m² UVA (EU) ( 315 nm - 380 nm) 81.6 µW/cm² = 0.816 W/m² tmp ( 315 nm - 400 nm) 103 µW/cm² = 1.03 W/m² UVA2 (medical definition) ( 320 nm - 340 nm) 4.91 µW/cm² = 0.0491 W/m² UVA (US) ( 320 nm - 380 nm) 80.4 µW/cm² = 0.804 W/m² UVA1 (variant) ( 335 nm - 380 nm) 76.6 µW/cm² = 0.766 W/m² UVA1 (medical) ( 340 nm - 400 nm) 97.1 µW/cm² = 0.971 W/m² vis. UVA ( 350 nm - 380 nm) 74 µW/cm² = 0.74 W/m² VIS Rep3 ( 350 nm - 600 nm) 4290 µW/cm² = 42.9 W/m² VIS Rep4 ( 350 nm - 700 nm) 5510 µW/cm² = 55.1 W/m² purple ( 380 nm - 420 nm) 245 µW/cm² = 2.45 W/m² VIS ( 380 nm - 780 nm) 5490 µW/cm² = 54.9 W/m² VIS2 ( 400 nm - 680 nm) 5370 µW/cm² = 53.7 W/m² PAR ( 400 nm - 700 nm) 5420 µW/cm² = 54.2 W/m² blue ( 420 nm - 490 nm) 1030 µW/cm² = 10.3 W/m² green ( 490 nm - 575 nm) 1960 µW/cm² = 19.6 W/m² yellow ( 575 nm - 585 nm) 451 µW/cm² = 4.51 W/m² orange ( 585 nm - 650 nm) 1530 µW/cm² = 15.3 W/m² red ( 650 nm - 780 nm) 276 µW/cm² = 2.76 W/m² IR2 ( 655 nm - 685 nm) 146 µW/cm² = 1.46 W/m² IRA ( 700 nm - 1400 nm) 73.4 µW/cm² = 0.734 W/m² IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
Erythema 3.93 UV-Index Pyrimidine dimerization of DNA 7.02 µW/cm² Photoceratitis 4.89 µW/cm² Photoconjunctivitis 4.48 µW/cm² DNA Damage 5.45 Vitamin D3 6.63 µW/cm² Photosynthesis 3430 µW/cm² Luminosity 20600 lx Human L-Cone 3130 µW/cm² Human M-Cone 2450 µW/cm² Human S-Cone 905 µW/cm² CIE X 2810 µW/cm² CIE Y 2880 µW/cm² CIE Z 1670 µW/cm² PAR PPFD 259 µmol/m²/s Extinction preD3 72.8 e-3*m²/mol Extinction Tachysterol 203 e-3*m²/mol Exctincition PreD3 58700 m²/mol Extinction Lumisterol 55.1 m²/mol Exctincition Tachysterol 254000 m²/mol Extinction 7DHC 67.4 m²/mol L-Cone 2740 µW/cm² M-Cone 1510 µW/cm² S-Cone 1610 µW/cm² U-Cone 444 µW/cm² UVR - ICNIRP 2004 6.9 Rel Biol Eff Melatonin Supression 1240 µW/cm² Blue Light Hazard 1010 µW/cm² (49.2 µW/cm² per 1000 lx) CIE 174:2006 PreVit D3 6.66 µW/cm² Lumen Reptil 15900 "pseudo-lx" Vitamin D3 Degradation 6.08 µW/cm² Actinic UV 6.86 µW/cm² (3.33 mW/klm) Exctincition Lumisterol 61700 m²/mol Exctincition 7DHC 72400 m²/mol Exctincition Toxisterols 15100 m²/mol UV-Index2 1.57 UV-Index (285-400nm)
Solarmeter 6.2 (UVB, pre 2010) 27.5 µW/cm² Solarmeter 6.5 (UV-Index, pre 2010) 2.33 Leybold UVB 15.1 µW/cm² Leybold UVA 57.5 µW/cm² Leybold UVC 3.32 µW/cm² DeltaOhm UVB 19.9 µW/cm² DeltaOhm UVC 6.91 µW/cm² Vernier UVB 7.33 µW/cm² Vernier UVA 33.3 µW/cm² Gröbel UVA 71.2 µW/cm² Gröbel UVB 11.6 µW/cm² Gröbel UVC 3.87 µW/cm² Luxmeter 21200 lx Solarmeter 6.4 (D3) 7.27 IU/min UVX-31 23.8 µW/cm² IL UVB 0.0105 µW/cm² IL UVA 76.4 µW/cm² Solarmeter 6.5 (UVI, post 2010) 1.71 UV-Index Solarmeter 6.2 (UVB, post 2010) 12.5 µW/cm² (Solarmeter Ratio = 7.33) Solarmeter AlGaN 6.5 UVI sensor 14.3 UV Index GenUV 7.1 UV-Index 0.879 UV-Index Solarmeter 10.0 (Global Power) (manuf.) 59.4 W/m² Solarmeter 4.0 (UVA) 1.39 mW/cm² LS122 (manuf.) 0.0233 W/m² ISM400 (first guess) 41.4 W/m² LS122 (assumption) 2.36 W/m² ISM400_new 33.1 W/m² Solarmeter 10.0 (Global Power) (assumption) 58.2 W/m²
| UVC (0nm -280nm) [µW/cm] | 5.01 | 0.0892 % |
| non-terrestrial (0nm -290nm) [µW/cm] | 6.81 | 0.121 % |
| UVB (EU) (280nm -315nm) [µW/cm] | 18.5 | 0.33 % |
| UVB (US) (280nm -320nm) [µW/cm] | 19.7 | 0.35 % |
| Solar UVB (290nm -315nm) [µW/cm] | 16.7 | 0.297 % |
| UVA (EU) (315nm -380nm) [µW/cm] | 81.6 | 1.45 % |
| UVA (US) (320nm -380nm) [µW/cm] | 80.4 | 1.43 % |
| UVA2 (medical definition) (320nm -340nm) [µW/cm] | 4.91 | 0.0875 % |
| UVA1 (medical) (340nm -400nm) [µW/cm] | 97.1 | 1.73 % |
| UVA D3 regulating (315nm -335nm) [µW/cm] | 4.93 | 0.0878 % |
| vis. UVA (350nm -380nm) [µW/cm] | 74 | 1.32 % |
| VIS (380nm -780nm) [µW/cm] | 5490 | 97.8 % |
| blue (420nm -490nm) [µW/cm] | 1030 | 18.4 % |
| total2 (250nm -880nm) [µW/cm] | 5620 | 100 % |
| UV-Index2 [UV-Index] | 1.57 | |
| Luminosity [lx] | 20600 | |
| Blue Light Hazard [µW/cm²] | 1010 | 49.2µW/cm/1000lx |
| Solarmeter 6.5 (UVI, post 2010) [UV-Index] | 1.71 | |
| Solarmeter 6.2 (UVB, post 2010) [µW/cm²] | 12.5 | |
| Actinic UV [µW/cm²] | 6.86 | 33.1 at UVI7.6 |
| Vitamin D3 [µW/cm²] | 6.63 | 32 at UVI7.6 |