Reptile Lamp Database

Spectrum #873
SW138 (Osram NATURA L 18W/76) Edit
Delete

(1) Raw Measurement

Spektrum
Lampid SW138
Spectrometer USB2000+
Originator Sarina Wunderlich
Ballast - no ballast or default/unknown ballast -
Reflector - no reflector -
Distance 5
Age 1
created by Sarina Wunderlich, 19.11.2026; last updated by , 19.11.2026
Description

CCT:1019 3106K
CRI DC:1017 3,09E-2
CRI R01:1002 67,4 (3106K)
CRI R02:1003 73,7 (3106K)
CRI R03:1004 72,9 (3106K)
CRI R04:1005 85,4 (3106K)
CRI R05:1006 84,9 (3106K)
CRI R06:1007 82,5 (3106K)
CRI R07:1008 87,1 (3106K)
CRI R08:1009 90,1 (3106K)
CRI R09:1010 77,3 (3106K)
CRI R10:1011 85,9 (3106K)
CRI R11:1012 92,1 (3106K)
CRI R12:1013 80,9 (3106K)
CRI R13:1014 59,2 (3106K)
CRI R14:1015 77,8 (3106K)
CRI R15:1016 63,0 (3106K)
CRI Ra:1001 80,5 (3106K)
DC<5.4E-3:1018 false
X:1022 14,76
Y:1023 12,07
Z:1024 10,75
x:1026 0,3927
y:1027 0,3213
z:1028 0,2860

(2) Comparison of full spectrum to sunlight

The spectrum is compared to the ASTM spectrum. The measured spectrum is scaled to a lux or UVI value that seems to "make sense" to the database. This can go wrong, depending on the quality and range of the data. Spektrum

(3) Colorimetry

Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.

Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (ASTM spectrum).

From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338 – 451, 511 – 513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.

Human (CIE) 3 cone reptile 4 cone reptile
Cone Excitation
Colour Coordinate (0.39 ; 0.32) (0.37 ; 0.53) (0.4 ; 0.23 ; 0.32)
CCT 3100 Kelvin 5500 Kelvin 3800 Kelvin
distance 0.18 0.14
colour space 3-D-graph not implemented yet

(4) Vitamin D3 Analysis

Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.

This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.

The ratio of the readings of two solarmeters 6.2 (UVB) and 6.5 (UV index) has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.

(5) Effective Irradiances

Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.

The calculation method is a numerical implementation (Simpson's rule) of the formula

To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).

The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists

  • range: UVB (US) = 13.8 µW/cm²
  • radiometer: Solarmeter 6.2 = 19.6 µW/cm²
then any Solarmeter 6.2 reading multiplied with 0.7 (0.7=13.8/19.6) is an estimate of UVB irradiance for this specific lamp. If you do so, always make sure, that the calculated (effective) irradiance is valid. The calculated value is not valid, if the lamp's spectrum is not measured in the relevant range.

(5a) Ranges
total ( 0 nm - 0 nm) 3360 µW/cm² = 33.6 W/m²
UVC ( 0 nm - 280 nm) 3.7 µW/cm² = 0.037 W/m²
non-terrestrial ( 0 nm - 290 nm) 5.09 µW/cm² = 0.0509 W/m²
total2 ( 250 nm - 880 nm) 3360 µW/cm² = 33.6 W/m²
UVB (EU) ( 280 nm - 315 nm) 5.04 µW/cm² = 0.0504 W/m²
UVB (US) ( 280 nm - 320 nm) 5.66 µW/cm² = 0.0566 W/m²
UVA+B ( 280 nm - 380 nm) 62.3 µW/cm² = 0.623 W/m²
Solar UVB ( 290 nm - 315 nm) 3.62 µW/cm² = 0.0362 W/m²
UVA D3 regulating ( 315 nm - 335 nm) 3.89 µW/cm² = 0.0389 W/m²
UVA (EU) ( 315 nm - 380 nm) 57.3 µW/cm² = 0.573 W/m²
tmp ( 315 nm - 400 nm) 66.7 µW/cm² = 0.667 W/m²
UVA2 (medical definition) ( 320 nm - 340 nm) 5.22 µW/cm² = 0.0522 W/m²
UVA (US) ( 320 nm - 380 nm) 56.7 µW/cm² = 0.567 W/m²
UVA1 (variant) ( 335 nm - 380 nm) 53.4 µW/cm² = 0.534 W/m²
UVA1 (medical) ( 340 nm - 400 nm) 60.8 µW/cm² = 0.608 W/m²
vis. UVA ( 350 nm - 380 nm) 46.1 µW/cm² = 0.461 W/m²
VIS Rep3 ( 350 nm - 600 nm) 1900 µW/cm² = 19 W/m²
VIS Rep4 ( 350 nm - 700 nm) 3150 µW/cm² = 31.5 W/m²
purple ( 380 nm - 420 nm) 95.3 µW/cm² = 0.953 W/m²
VIS ( 380 nm - 780 nm) 3240 µW/cm² = 32.4 W/m²
VIS2 ( 400 nm - 680 nm) 3040 µW/cm² = 30.4 W/m²
PAR ( 400 nm - 700 nm) 3100 µW/cm² = 31 W/m²
blue ( 420 nm - 490 nm) 776 µW/cm² = 7.76 W/m²
green ( 490 nm - 575 nm) 718 µW/cm² = 7.18 W/m²
yellow ( 575 nm - 585 nm) 90.8 µW/cm² = 0.908 W/m²
orange ( 585 nm - 650 nm) 1180 µW/cm² = 11.8 W/m²
red ( 650 nm - 780 nm) 377 µW/cm² = 3.77 W/m²
IR2 ( 655 nm - 685 nm) 153 µW/cm² = 1.53 W/m²
IRA ( 700 nm - 1400 nm) 190 µW/cm² = 1.9 W/m²
IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
(5b) Actionspectra
Erythema 2.6 UV-Index
Pyrimidine dimerization of DNA 2.25 µW/cm²
Photoceratitis 3.05 µW/cm²
Photoconjunctivitis 3.27 µW/cm²
DNA Damage 3.98
Vitamin D3 3.63 µW/cm²
Photosynthesis 2150 µW/cm²
Luminosity 9460 lx
Human L-Cone 1490 µW/cm²
Human M-Cone 1020 µW/cm²
Human S-Cone 620 µW/cm²
CIE X 1590 µW/cm²
CIE Y 1300 µW/cm²
CIE Z 1160 µW/cm²
PAR PPFD 147 µmol/m²/s
Extinction preD3 45 e-3*m²/mol
Extinction Tachysterol 123 e-3*m²/mol
Exctincition PreD3 39500 m²/mol
Extinction Lumisterol 40.2 m²/mol
Exctincition Tachysterol 155000 m²/mol
Extinction 7DHC 49.5 m²/mol
L-Cone 1340 µW/cm²
M-Cone 759 µW/cm²
S-Cone 1060 µW/cm²
U-Cone 202 µW/cm²
UVR - ICNIRP 2004 4.97 Rel Biol Eff
Melatonin Supression 805 µW/cm²
Blue Light Hazard 685 µW/cm² (72.4 µW/cm² per 1000 lx)
CIE 174:2006 PreVit D3 3.63 µW/cm²
Lumen Reptil 8370 "pseudo-lx"
Vitamin D3 Degradation 3.07 µW/cm²
Actinic UV 4.94 µW/cm² (5.22 mW/klm)
Exctincition Lumisterol 44800 m²/mol
Exctincition 7DHC 53000 m²/mol
Exctincition Toxisterols 9260 m²/mol
UV-Index2 0.852 UV-Index (285-400nm)
(5c) Broadbandmeters
Solarmeter 6.2 (UVB, pre 2010) 12 µW/cm²
Solarmeter 6.5 (UV-Index, pre 2010) 1.4
Leybold UVB 4.01 µW/cm²
Leybold UVA 42.1 µW/cm²
Leybold UVC 2.36 µW/cm²
DeltaOhm UVB 7.87 µW/cm²
DeltaOhm UVC 3.76 µW/cm²
Vernier UVB 2.79 µW/cm²
Vernier UVA 23.5 µW/cm²
Gröbel UVA 48.7 µW/cm²
Gröbel UVB 4.86 µW/cm²
Gröbel UVC 2.83 µW/cm²
Luxmeter 9030 lx
Solarmeter 6.4 (D3) 4.39 IU/min
UVX-31 10.7 µW/cm²
IL UVB 0.00491 µW/cm²
IL UVA 52.6 µW/cm²
Solarmeter 6.5 (UVI, post 2010) 0.98 UV-Index
Solarmeter 6.2 (UVB, post 2010) 4.65 µW/cm² (Solarmeter Ratio = 4.74)
Solarmeter AlGaN 6.5 UVI sensor 5.07 UV Index
GenUV 7.1 UV-Index 0.372 UV-Index
Solarmeter 10.0 (Global Power) (manuf.) 36.9 W/m²
Solarmeter 4.0 (UVA) 0.807 mW/cm²
LS122 (manuf.) 0.0842 W/m²
ISM400 (first guess) 27.7 W/m²
LS122 (assumption) 1.56 W/m²
ISM400_new 23.3 W/m²
Solarmeter 10.0 (Global Power) (assumption) 36.2 W/m²
(5d) Summary of my favourites
UVC (0nm -280nm) [µW/cm] 3.7 0.11 %
non-terrestrial (0nm -290nm) [µW/cm] 5.09 0.151 %
UVB (EU) (280nm -315nm) [µW/cm] 5.04 0.15 %
UVB (US) (280nm -320nm) [µW/cm] 5.66 0.169 %
Solar UVB (290nm -315nm) [µW/cm] 3.62 0.108 %
UVA (EU) (315nm -380nm) [µW/cm] 57.3 1.7 %
UVA (US) (320nm -380nm) [µW/cm] 56.7 1.69 %
UVA2 (medical definition) (320nm -340nm) [µW/cm] 5.22 0.155 %
UVA1 (medical) (340nm -400nm) [µW/cm] 60.8 1.81 %
UVA D3 regulating (315nm -335nm) [µW/cm] 3.89 0.116 %
vis. UVA (350nm -380nm) [µW/cm] 46.1 1.37 %
VIS (380nm -780nm) [µW/cm] 3240 96.5 %
blue (420nm -490nm) [µW/cm] 776 23.1 %
total2 (250nm -880nm) [µW/cm] 3360 100 %
UV-Index2 [UV-Index] 0.852
Luminosity [lx] 9460
Blue Light Hazard [µW/cm²] 685 72.4µW/cm/1000lx
Solarmeter 6.5 (UVI, post 2010) [UV-Index] 0.98
Solarmeter 6.2 (UVB, post 2010) [µW/cm²] 4.65
Actinic UV [µW/cm²] 4.94 44.1 at UVI7.6
Vitamin D3 [µW/cm²] 3.63 32.4 at UVI7.6