Reptile Lamp Database

Spectrum #871
SW133 (Zoo Med Reptisun 5.0 UVB T5 24W) Edit
Delete

(1) Raw Measurement

Spektrum
Lampid SW133
Spectrometer USB2000+
Originator Sarina Wunderlich
Ballast - no ballast or default/unknown ballast -
Reflector Arcadia ProT5 HO T5 UV-B Lighting Kit
Distance 10
Age 100
created by Sarina Wunderlich, 07.11.2026; last updated by , 07.11.2026
Description

(2) Comparison of full spectrum to sunlight

The spectrum is compared to the ASTM spectrum. The measured spectrum is scaled to a lux or UVI value that seems to "make sense" to the database. This can go wrong, depending on the quality and range of the data. Spektrum

(3) Colorimetry

Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.

Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (ASTM spectrum).

From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338 – 451, 511 – 513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.

Human (CIE) 3 cone reptile 4 cone reptile
Cone Excitation
Colour Coordinate (0.31 ; 0.3) (0.26 ; 0.44) (0.24 ; 0.2 ; 0.33)
CCT 6900 Kelvin 8900 Kelvin 6900 Kelvin
distance 0.1 0.087
colour space 3-D-graph not implemented yet

(4) Vitamin D3 Analysis

Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.

This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.

The ratio of the readings of two solarmeters 6.2 (UVB) and 6.5 (UV index) has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.

(5) Effective Irradiances

Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.

The calculation method is a numerical implementation (Simpson's rule) of the formula

To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).

The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists

  • range: UVB (US) = 13.8 µW/cm²
  • radiometer: Solarmeter 6.2 = 19.6 µW/cm²
then any Solarmeter 6.2 reading multiplied with 0.7 (0.7=13.8/19.6) is an estimate of UVB irradiance for this specific lamp. If you do so, always make sure, that the calculated (effective) irradiance is valid. The calculated value is not valid, if the lamp's spectrum is not measured in the relevant range.

(5a) Ranges
total ( 0 nm - 0 nm) 7300 µW/cm² = 73 W/m²
UVC ( 0 nm - 280 nm) 3 µW/cm² = 0.03 W/m²
non-terrestrial ( 0 nm - 290 nm) 3.84 µW/cm² = 0.0384 W/m²
total2 ( 250 nm - 880 nm) 7310 µW/cm² = 73.1 W/m²
UVB (EU) ( 280 nm - 315 nm) 273 µW/cm² = 2.73 W/m²
UVB (US) ( 280 nm - 320 nm) 435 µW/cm² = 4.35 W/m²
UVA+B ( 280 nm - 380 nm) 2670 µW/cm² = 26.7 W/m²
Solar UVB ( 290 nm - 315 nm) 272 µW/cm² = 2.72 W/m²
UVA D3 regulating ( 315 nm - 335 nm) 745 µW/cm² = 7.45 W/m²
UVA (EU) ( 315 nm - 380 nm) 2390 µW/cm² = 23.9 W/m²
UVA2 (medical definition) ( 320 nm - 340 nm) 813 µW/cm² = 8.13 W/m²
UVA (US) ( 320 nm - 380 nm) 2230 µW/cm² = 22.3 W/m²
UVA1 (variant) ( 335 nm - 380 nm) 1650 µW/cm² = 16.5 W/m²
UVA1 (medical) ( 340 nm - 400 nm) 1540 µW/cm² = 15.4 W/m²
vis. UVA ( 350 nm - 380 nm) 913 µW/cm² = 9.13 W/m²
VIS Rep3 ( 350 nm - 600 nm) 4510 µW/cm² = 45.1 W/m²
VIS Rep4 ( 350 nm - 700 nm) 5420 µW/cm² = 54.2 W/m²
purple ( 380 nm - 420 nm) 374 µW/cm² = 3.74 W/m²
VIS ( 380 nm - 780 nm) 4600 µW/cm² = 46 W/m²
VIS2 ( 400 nm - 680 nm) 4360 µW/cm² = 43.6 W/m²
PAR ( 400 nm - 700 nm) 4390 µW/cm² = 43.9 W/m²
blue ( 420 nm - 490 nm) 1570 µW/cm² = 15.7 W/m²
green ( 490 nm - 575 nm) 1300 µW/cm² = 13 W/m²
yellow ( 575 nm - 585 nm) 169 µW/cm² = 1.69 W/m²
orange ( 585 nm - 650 nm) 989 µW/cm² = 9.89 W/m²
tmp ( 600 nm - 1000 nm) 1040 µW/cm² = 10.4 W/m²
red ( 650 nm - 780 nm) 194 µW/cm² = 1.94 W/m²
IR2 ( 655 nm - 685 nm) 59.5 µW/cm² = 0.595 W/m²
IRA ( 700 nm - 1400 nm) 125 µW/cm² = 1.25 W/m²
IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
(5b) Actionspectra
Erythema 17 UV-Index
Pyrimidine dimerization of DNA 165 µW/cm²
Photoceratitis 26 µW/cm²
Photoconjunctivitis 2.87 µW/cm²
DNA Damage 4.44
Vitamin D3 68.1 µW/cm²
Photosynthesis 3070 µW/cm²
Luminosity 13400 lx
Human L-Cone 2000 µW/cm²
Human M-Cone 1670 µW/cm²
Human S-Cone 1290 µW/cm²
CIE X 1910 µW/cm²
CIE Y 1850 µW/cm²
CIE Z 2370 µW/cm²
PAR PPFD 204 µmol/m²/s
Extinction preD3 491 e-3*m²/mol
Extinction Tachysterol 1710 e-3*m²/mol
Exctincition PreD3 251000 m²/mol
Extinction Lumisterol 84 m²/mol
Exctincition Tachysterol 2520000 m²/mol
Extinction 7DHC 79.5 m²/mol
L-Cone 1660 µW/cm²
M-Cone 1380 µW/cm²
S-Cone 2300 µW/cm²
U-Cone 1550 µW/cm²
UVR - ICNIRP 2004 14.5 Rel Biol Eff
Melatonin Supression 1630 µW/cm²
Blue Light Hazard 1460 µW/cm² (109 µW/cm² per 1000 lx)
CIE 174:2006 PreVit D3 74.5 µW/cm²
Lumen Reptil 15000 "pseudo-lx"
Vitamin D3 Degradation 85.5 µW/cm²
Actinic UV 14.4 µW/cm² (10.8 mW/klm)
Exctincition Lumisterol 115000 m²/mol
Exctincition 7DHC 97300 m²/mol
Exctincition Toxisterols 56300 m²/mol
UV-Index2 15.8 UV-Index (285-400nm)
(5c) Broadbandmeters
Solarmeter 6.2 (UVB, pre 2010) 528 µW/cm²
Solarmeter 6.5 (UV-Index, pre 2010) 19.9
Leybold UVB 377 µW/cm²
Leybold UVA 1670 µW/cm²
Leybold UVC 2.04 µW/cm²
DeltaOhm UVB 958 µW/cm²
DeltaOhm UVC 112 µW/cm²
Vernier UVB 124 µW/cm²
Vernier UVA 1580 µW/cm²
Gröbel UVA 2040 µW/cm²
Gröbel UVB 190 µW/cm²
Gröbel UVC 2.04 µW/cm²
Luxmeter 13600 lx
Solarmeter 6.4 (D3) 62.2 IU/min
UVX-31 1090 µW/cm²
IL UVB 0.23 µW/cm²
IL UVA 1870 µW/cm²
Solarmeter 6.5 (UVI, post 2010) 16.6 UV-Index
Solarmeter 6.2 (UVB, post 2010) 355 µW/cm² (Solarmeter Ratio = 21.4)
Solarmeter AlGaN 6.5 UVI sensor 231 UV Index
GenUV 7.1 UV-Index 13.1 UV-Index
Solarmeter 10.0 (Global Power) (manuf.) 56.7 W/m²
Solarmeter 4.0 (UVA) 24.1 mW/cm²
LS122 (manuf.) 0.0358 W/m²
ISM400 (first guess) 31 W/m²
LS122 (assumption) 1.49 W/m²
ISM400_new 24.1 W/m²
Solarmeter 10.0 (Global Power) (assumption) 48 W/m²
(5d) Summary of my favourites
UVC (0nm -280nm) [µW/cm] 3 0.041 %
non-terrestrial (0nm -290nm) [µW/cm] 3.84 0.0526 %
UVB (EU) (280nm -315nm) [µW/cm] 273 3.73 %
UVB (US) (280nm -320nm) [µW/cm] 435 5.96 %
Solar UVB (290nm -315nm) [µW/cm] 272 3.72 %
UVA (EU) (315nm -380nm) [µW/cm] 2390 32.8 %
UVA (US) (320nm -380nm) [µW/cm] 2230 30.6 %
UVA2 (medical definition) (320nm -340nm) [µW/cm] 813 11.1 %
UVA1 (medical) (340nm -400nm) [µW/cm] 1540 21 %
UVA D3 regulating (315nm -335nm) [µW/cm] 745 10.2 %
vis. UVA (350nm -380nm) [µW/cm] 913 12.5 %
VIS (380nm -780nm) [µW/cm] 4600 63 %
blue (420nm -490nm) [µW/cm] 1570 21.5 %
total2 (250nm -880nm) [µW/cm] 7310 100 %
UV-Index2 [UV-Index] 15.8
Luminosity [lx] 13400
Blue Light Hazard [µW/cm²] 1460 109µW/cm/1000lx
Solarmeter 6.5 (UVI, post 2010) [UV-Index] 16.6
Solarmeter 6.2 (UVB, post 2010) [µW/cm²] 355
Actinic UV [µW/cm²] 14.4 6.92 at UVI7.6
Vitamin D3 [µW/cm²] 68.1 32.7 at UVI7.6