Reptile Lamp Database

Spectrum #868
SW135 (Zoo Med Reptisun 10.0 UVB T5 24W) Edit
Delete

(1) Raw Measurement

Spektrum
Lampid SW135
Spectrometer USB2000+
Originator Sarina Wunderlich
Ballast - no ballast or default/unknown ballast -
Reflector Arcadia ProT5 HO T5 UV-B Lighting Kit
Distance 10
Age 100
created by Sarina Wunderlich, 02.11.2026; last updated by , 02.11.2026
Description

(2) Comparison of full spectrum to sunlight

The spectrum is compared to the ASTM spectrum. The measured spectrum is scaled to a lux or UVI value that seems to "make sense" to the database. This can go wrong, depending on the quality and range of the data. Spektrum

(3) Colorimetry

Colorimetry is the science to describe physically the human color perception. The wavelength range 380 nm - 780 nm is visible to humans and detected by three different photoreceptors. Many Reptiles see the range 350 nm - 800 nm and have an additional UV photoreceptor in their retina.

Whereas a spectrometer measures the intensity in every tiny wavelength interval resulting in thousands of individual intensities, the human eye only measures three intensities detected by the three cones. The same is true for the reptile eye with usually three or four photoreceptors. Effectively the detailled spectrum displayed above reduces to a much compacter bar graph displayed below. The photoreceptor sensitivites from these L-Cone, M-Cone, S-Cone, and U-Cone are used, they are chosen as an average of measured reptile photoreceptor sensitivity curves. The bar graph also shows as reference the intensity seen by the three or four photoreceptors for average sunlight (ASTM spectrum).

From these three numbers the colour coordinate and the correlated colour temperature for humans are calculated using the CIE standard method. I adapted this concept to a "3 cone reptile (M,S,U)" and a "4 cone reptile (L,M,S,U)". I am sure, that this adaption to other colour spaces makes sense mathematically and this is also done in scientific research regarding colour vision of animals, however I have not seen calculation of colour temperatures for other animals in the scientific literature. Even if it is hypothetical, at least this shows, how arbitrary the colour temperature is, and that the colour temperature calculated for humans does not apply to reptiles. The colour spaces also show the colour coordinates of different phases of daylight ((ids 1, 338 – 451, 511 – 513 ), indicated by crosses, coloured in the appriximate colour perceived by a human.

Human (CIE) 3 cone reptile 4 cone reptile
Cone Excitation
Colour Coordinate (0.35 ; 0.33) (0.14 ; 0.29) (0.21 ; 0.11 ; 0.23)
CCT 4600 Kelvin 0 Kelvin 14000 Kelvin
distance 0 0.13
colour space 3-D-graph not implemented yet

(4) Vitamin D3 Analysis

Vitamin D3 is produced by UVB radiation around 300 nm. 7DHC/ProD3 present in the skin is converted to PreD3 when absorbing an UV photon. PreD3 can be converted back to ProD3, to Lumisterol, or to Tachysterol when absorbing another UV photon or can be converted to Vitamin D3 in a warm environment.

This process prevents any overdose of vitamin D3 from UV radiation with a spectrum similar to sunlight. As a comparison the solar spectra at 20°(id:14) and at 85°(id:21) solar angle are shown.

The ratio of the readings of two solarmeters 6.2 (UVB) and 6.5 (UV index) has proven a useful and very simply number to acess the spectral shape in the vitamin-d3-active region.

(5) Effective Irradiances

Effective irradiances are calculated for all ranges, actionspectra and radiometers currently present in this database.

The calculation method is a numerical implementation (Simpson's rule) of the formula

To learn more about calculating effective irradiances and radiometers I recommend this excellent report on UVB meters: Characterizing the Performance of Integral Measuring UV-Meters (pdf).

The numbers in the following tables can also be used to estimate certain (effective) irradiances from radiomer readings. Example: If the database lists

  • range: UVB (US) = 13.8 µW/cm²
  • radiometer: Solarmeter 6.2 = 19.6 µW/cm²
then any Solarmeter 6.2 reading multiplied with 0.7 (0.7=13.8/19.6) is an estimate of UVB irradiance for this specific lamp. If you do so, always make sure, that the calculated (effective) irradiance is valid. The calculated value is not valid, if the lamp's spectrum is not measured in the relevant range.

(5a) Ranges
total ( 0 nm - 0 nm) 7750 µW/cm² = 77.5 W/m²
UVC ( 0 nm - 280 nm) 5.17 µW/cm² = 0.0517 W/m²
non-terrestrial ( 0 nm - 290 nm) 8.54 µW/cm² = 0.0854 W/m²
total2 ( 250 nm - 880 nm) 7750 µW/cm² = 77.5 W/m²
UVB (EU) ( 280 nm - 315 nm) 544 µW/cm² = 5.44 W/m²
UVB (US) ( 280 nm - 320 nm) 878 µW/cm² = 8.78 W/m²
UVA+B ( 280 nm - 380 nm) 5010 µW/cm² = 50.1 W/m²
Solar UVB ( 290 nm - 315 nm) 540 µW/cm² = 5.4 W/m²
UVA D3 regulating ( 315 nm - 335 nm) 1510 µW/cm² = 15.1 W/m²
UVA (EU) ( 315 nm - 380 nm) 4470 µW/cm² = 44.7 W/m²
UVA2 (medical definition) ( 320 nm - 340 nm) 1620 µW/cm² = 16.2 W/m²
UVA (US) ( 320 nm - 380 nm) 4140 µW/cm² = 41.4 W/m²
UVA1 (variant) ( 335 nm - 380 nm) 2960 µW/cm² = 29.6 W/m²
UVA1 (medical) ( 340 nm - 400 nm) 2690 µW/cm² = 26.9 W/m²
vis. UVA ( 350 nm - 380 nm) 1550 µW/cm² = 15.5 W/m²
VIS Rep3 ( 350 nm - 600 nm) 3560 µW/cm² = 35.6 W/m²
VIS Rep4 ( 350 nm - 700 nm) 4180 µW/cm² = 41.8 W/m²
purple ( 380 nm - 420 nm) 400 µW/cm² = 4 W/m²
VIS ( 380 nm - 780 nm) 2700 µW/cm² = 27 W/m²
VIS2 ( 400 nm - 680 nm) 2430 µW/cm² = 24.3 W/m²
PAR ( 400 nm - 700 nm) 2450 µW/cm² = 24.5 W/m²
blue ( 420 nm - 490 nm) 663 µW/cm² = 6.63 W/m²
green ( 490 nm - 575 nm) 702 µW/cm² = 7.02 W/m²
yellow ( 575 nm - 585 nm) 130 µW/cm² = 1.3 W/m²
orange ( 585 nm - 650 nm) 669 µW/cm² = 6.69 W/m²
tmp ( 600 nm - 1000 nm) 724 µW/cm² = 7.24 W/m²
red ( 650 nm - 780 nm) 131 µW/cm² = 1.31 W/m²
IR2 ( 655 nm - 685 nm) 34.1 µW/cm² = 0.341 W/m²
IRA ( 700 nm - 1400 nm) 98 µW/cm² = 0.98 W/m²
IRB ( 1400 nm - 3000 nm) 0 µW/cm² = 0 W/m²
(5b) Actionspectra
Erythema 35.1 UV-Index
Pyrimidine dimerization of DNA 336 µW/cm²
Photoceratitis 53.8 µW/cm²
Photoconjunctivitis 5.33 µW/cm²
DNA Damage 8.82
Vitamin D3 141 µW/cm²
Photosynthesis 1650 µW/cm²
Luminosity 7930 lx
Human L-Cone 1210 µW/cm²
Human M-Cone 939 µW/cm²
Human S-Cone 588 µW/cm²
CIE X 1170 µW/cm²
CIE Y 1100 µW/cm²
CIE Z 1060 µW/cm²
PAR PPFD 121 µmol/m²/s
Extinction preD3 997 e-3*m²/mol
Extinction Tachysterol 3500 e-3*m²/mol
Exctincition PreD3 507000 m²/mol
Extinction Lumisterol 184 m²/mol
Exctincition Tachysterol 5130000 m²/mol
Extinction 7DHC 182 m²/mol
L-Cone 1040 µW/cm²
M-Cone 550 µW/cm²
S-Cone 1160 µW/cm²
U-Cone 2250 µW/cm²
UVR - ICNIRP 2004 31.2 Rel Biol Eff
Melatonin Supression 715 µW/cm²
Blue Light Hazard 719 µW/cm² (90.7 µW/cm² per 1000 lx)
CIE 174:2006 PreVit D3 155 µW/cm²
Lumen Reptil 9890 "pseudo-lx"
Vitamin D3 Degradation 174 µW/cm²
Actinic UV 31 µW/cm² (39 mW/klm)
Exctincition Lumisterol 252000 m²/mol
Exctincition 7DHC 222000 m²/mol
Exctincition Toxisterols 95600 m²/mol
UV-Index2 32.3 UV-Index (285-400nm)
(5c) Broadbandmeters
Solarmeter 6.2 (UVB, pre 2010) 1070 µW/cm²
Solarmeter 6.5 (UV-Index, pre 2010) 41.6
Leybold UVB 759 µW/cm²
Leybold UVA 3080 µW/cm²
Leybold UVC 2.93 µW/cm²
DeltaOhm UVB 1920 µW/cm²
DeltaOhm UVC 226 µW/cm²
Vernier UVB 255 µW/cm²
Vernier UVA 3020 µW/cm²
Gröbel UVA 3800 µW/cm²
Gröbel UVB 385 µW/cm²
Gröbel UVC 3.37 µW/cm²
Luxmeter 7990 lx
Solarmeter 6.4 (D3) 130 IU/min
UVX-31 2160 µW/cm²
IL UVB 0.464 µW/cm²
IL UVA 3430 µW/cm²
Solarmeter 6.5 (UVI, post 2010) 34.2 UV-Index
Solarmeter 6.2 (UVB, post 2010) 717 µW/cm² (Solarmeter Ratio = 20.9)
Solarmeter AlGaN 6.5 UVI sensor 466 UV Index
GenUV 7.1 UV-Index 26.5 UV-Index
Solarmeter 10.0 (Global Power) (manuf.) 47.9 W/m²
Solarmeter 4.0 (UVA) 43.7 mW/cm²
LS122 (manuf.) 0.0423 W/m²
ISM400 (first guess) 20.5 W/m²
LS122 (assumption) 0.985 W/m²
ISM400_new 15.8 W/m²
Solarmeter 10.0 (Global Power) (assumption) 34.8 W/m²
(5d) Summary of my favourites
UVC (0nm -280nm) [µW/cm] 5.17 0.0668 %
non-terrestrial (0nm -290nm) [µW/cm] 8.54 0.11 %
UVB (EU) (280nm -315nm) [µW/cm] 544 7.02 %
UVB (US) (280nm -320nm) [µW/cm] 878 11.3 %
Solar UVB (290nm -315nm) [µW/cm] 540 6.98 %
UVA (EU) (315nm -380nm) [µW/cm] 4470 57.7 %
UVA (US) (320nm -380nm) [µW/cm] 4140 53.4 %
UVA2 (medical definition) (320nm -340nm) [µW/cm] 1620 21 %
UVA1 (medical) (340nm -400nm) [µW/cm] 2690 34.7 %
UVA D3 regulating (315nm -335nm) [µW/cm] 1510 19.4 %
vis. UVA (350nm -380nm) [µW/cm] 1550 20.1 %
VIS (380nm -780nm) [µW/cm] 2700 34.8 %
blue (420nm -490nm) [µW/cm] 663 8.56 %
total2 (250nm -880nm) [µW/cm] 7750 100 %
UV-Index2 [UV-Index] 32.3
Luminosity [lx] 7930
Blue Light Hazard [µW/cm²] 719 90.7µW/cm/1000lx
Solarmeter 6.5 (UVI, post 2010) [UV-Index] 34.2
Solarmeter 6.2 (UVB, post 2010) [µW/cm²] 717
Actinic UV [µW/cm²] 31 7.28 at UVI7.6
Vitamin D3 [µW/cm²] 141 33.2 at UVI7.6