2006: change to lamps with slits in base 2009: change to lamps with yellowish phsophor without <290nm radiation
Database entry created: Sarina Wunderlich
23/Sep/2009 ; updated:
Sarina Wunderlich
23/Mar/2021
2006: change to lamps with slits in base 2009: change to lamps with yellowish phsophor without <290nm radiation
Lamp ID | Purchased | Description |
---|---|---|
DZR11 | 01/2005 | |
LGFP-RS2 | 01/2008 | JUKKA LINDGREN, WILLIAM H. GEHRMANN, GARY W. FERGUSON & JOHN E. PINDER. 2008. Measuring Effective Vitamin D3-Producing Ultraviolet B Radiation Using Solartech’s Solarmeter® 6.4 Handheld, UVB Radiometer. Bulletin of the Chicago Herpetological Society 43.4. 57–62. |
BZC19 | 09/2009 | New version launched in 2009 to replace lamps with very short-wavelength UVB |
DK07 | 06/2019 | https://saharych.blogspot.com/2019/10/zoo-med-reptisun-100-26.html |
TG-ZM-10.0-26W-001 | 09/2023 | Zoo Med Lamp - 2023 |
Click on the broadbandmeter to get more information about the broadbandmeter. Click on or use mouse-over on the measured value to get more information about the measurement.
Broadbandmeter | Age \ Distance | 0 cm | 10 cm | 20 cm | 23 cm | 30 cm | 33 cm |
---|---|---|---|---|---|---|---|
Solarmeter 6.2 (UVB, pre 2010) | 100 h | 11 | |||||
DeltaOhm UVB | 0.08 h | 952 | |||||
DeltaOhm UVC | 0.08 h | 35.1 | |||||
Solarmeter 6.4 (D3) | 100 h | 6 | |||||
Solarmeter 6.5 (UVI, post 2010) | 1 h | 2.3; 3.4; 5.8 | 0.7; 1.2; 1.8 | 0.3; 0.6; 0.9 | |||
Solarmeter 6.5 (UVI, post 2010) | 25 h | 2.1; 3; 5.4; 7.6 | 0.6; 1; 1.7; 2.5 | 2 | 0.3; 0.5; 0.8; 1.1 | 1 | |
Solarmeter 6.5 (UVI, post 2010) | 500 h | 4 | 1.3 | 0.6 | |||
Solarmeter 6.5 (UVI, post 2010) | 1000 h | 3.2 | 1 | 0.5 | |||
Solarmeter 6.5 (UVI, post 2010) | 1500 h | 2.7 | 0.8 | 0.4 |